VIP SENSORS introduces a new product - The Model 2017A is an adhesively mounted piezoelectric accelerometer with integral electronics (IEPE) that is ideally suited for vibration measurements on small structures and objects. Along with a mass of only 5 grams, it features a high signal-to-noise ratio, two output sensitivities (10 mV/g and 100 mV/g) and a wide bandwidth up to 6 kHz. The accelerometer transmits its low impedance voltage output through the same cable that supplies the constant current power. The Model 2017A design is sealed against external contamination. The accelerometer features a top connector that is used with a 10-foot coaxial cable terminated with a 10-32 connector for error-free operation. VIP Sensors offers a range of piezoelectric and voltage mode accelerometers, signal conditioners, data acquisition systems, cable assemblies and accessories. Shock and vibration calibration services are also available for all types of accelerometers. The company’s strength is in its technical expertise in sensor and electronics design. VIP Sensors’ goal is to provide state-of-the-art, quality products at a very competitive price. DYNAMIC CHARACTERISTICS • Range g (m/s2) 500 (4903.3) 50 (490.3) • Voltage Sensitivity, typical mV/g (mV/m/s2) 10 (1.02) 100 (10.2) • Transverse Sensitivity % ? 5 • Frequency Response See Typical Amplitude Response • Resonance Frequency Hz 20,000 • Amplitude Response • + 5 % Hz 1 – 5,000 • + 1 dB Hz 0.5 –6,000 • Temperature Response See Typical Temperature Response • Amplitude Linearity % < 1 ELECTRICAL CHARACTERISTICS • Output Polarity Acceleration directed from base into the transducer • defined as positive • Power Source Voltage • (Constant Current) • VDC +18 to +28 • Supply Current mA 2 to 10 • Bias Voltage V 11 +1 • Full Scale Output Voltage (peak) Vp ? 5 • Output Impedance ? < 300 • Noise mg (mm/s2) < 0.8 (< 7.8) < 0.08 (< 0.78) • Grounding Signal ground connected to case ENVIRONMENTAL CHARACTERISTICS • Temperature Range -40°F to 248°F (-40°C to +120°C) • Humidity Epoxy sealed • Shock Limit g pk (m/s2 pk) 2,000 (19,613) • Base Strain equiv. g /?strain 0.0002 0.002 • Magnetic Field Sensitivity equiv. g rms /gauss • (/T) • 2E-5 (2) 2E-4 (2) • Thermal Transient Sensitivity equiv. g /°C 0.008 0.008 PHYSICAL CHARACTERISTICS • Weight oz (grams) 0.19 (5.3) • Case Material Stainless Steel • Mounting Adhesive • Piezoelectric Material PZT-5 • Structure Annular Shear • Output Connector 10-32 receptacle, top mounting ACCESSORIES Included: Optional: 9005L10 Coaxial Cable 10-32/BNC, 10ft (3.3 m) 9006L10 Coaxial Cable 10-32/10-32, 10 ft (3.3 m) Calibration Sheet 9505-15 Isolated Adhesive Mounting Plate NOTES 1. Short duration shock pulses, such as those generated by metal-to-metal impacts, may excite transducer resonance and cause linearity errors.