Model VA Belt Alignment Control for Bucket Elevators
Protect your valuable conveyor belt from severe damage caused by belt misalignment, prevent costly downtime, and increase production with the Model VA belt alignment control. Designed for use on bucket elevators, the Model VA ensures that your belt is tracking properly. Normally installed in pairs on each side of the conveyor belt near the head pulley and/or the tail pulley, these controls consist of a conveyor roller with sealed bearings, four-bar linkage, and a double pole/double throw microswitch.
The roller detects any belt run-off and will trigger the first pole of the microswitch to sound a warning alarm, illuminate an indicator light or stop the conveyor completely when the vertical belt strays beyond 10-deg. from horizontal. The second pole is triggered when the belt strays 25-deg. from horizontal and can be wired to stop the conveyor motor. To eliminate false signals the controls should be mounted about one inch away from the belt.
For high-speed conveyors, a breakaway mount is recommended. In the event of a run-off, the control unit performs its job of shutting down the conveyor and the breakaway mount allows the control itself to get out of the way of damage. The Model VA general-purpose microswitch enclosure is UL-Listed and CSA Certified, Rated NEMA Type 4.
The Model VA-X is our explosion-proof model rated NEMA Type 1, 3, 4, 6, 13; Type 7, Class I, Groups B, C, D; NEMA Type 9, Class II, E, F, and G for use in hazardous environments.
break microswitch
0.15A ind, 0.4A res 125V DC:
0.25A ind, 0.8A res 24V DC: 10A
Type 7: Class I (Div. 1 & 2),
Groups B, C & D;
Type 9: Class II (Div. 1 & 2),
Groups E, F & G