A temperature profiling system that addresses the needs of any paint or powder coating operation is the DATAPAQ EasyTrack3. A comprehensive range of thermal barriers protects the data logger with its non-volatile memory in infrared and convection ovens. The lightweight aluminum standard barrier shields the electronics for up to 2 hours at 200°C. Thermal protection is ensured by high-performance microporous insulation and a heat sink.
The DATAPAQ EasyTrack3 Professional System extends protection to 3 hours, allowing users to monitor up to three cure processes consecutively. A thermal barrier for high-temperature PTFE and Dacromet coating withstands 400°C for up to 90 min. The manufacturer has designed a low-height barrier for profiling typical mesh belt cure lines where oven clearance is significantly restricted. At merely 31 mm high, the barrier provides protection for a full 13 min at 200°C or for 30 min at 100°C.
The logger operating temperature is 85°C. It automatically switches off, should it ever heat above that point. This prevents faulty data collection. The profiler provides measurement accuracy of ±1.6°C (logger and thermocouple accuracy combined) over its entire operating temperature range. The robust, tried-and-tested system ensures successful measurements day after day.
- Easy-to-use thermal profiling system designed for the Industrial Powder Coating market
- Selection of light-weight yet robust thermal barriers to suit specific application needs
- Improved ET3 logger design with more memory, battery life and onboard intelligence
- New EasyTrack Insight Professional Software option with more operation, analysis, & reporting power
- New capabilities with Multiple runs & SmartPaq (Run PASS/FAIL directly from logger)